Hero background
GRP Trench & Draw Pit Cover Systems

GRP Trench & Draw Pit Cover Systems

Background Pattern
Why {GRP Trench & Draw Pit Cover Systems} Matter

Why GRP Trench & Draw Pit Cover Systems Matter

Unprotected trenches and draw pits are high-risk environments. Without adequate coverage, they create fall hazards, structural vulnerability, and non-compliance, putting lives and operations at risk. Our GRP cover systems are engineered to perform under load, resist chemicals and deliver lasting structural integrity, ensuring compliance and safety across demanding facility environments. Without engineered containment solutions:

Without engineered containment solutions:
Open pits and trenches create serious fall risks, putting workers and site compliance in jeopardy.
Standard covers fail under heavy loads, exposing structural gaps and causing unplanned operational downtime.
Chemical exposure and moisture corrode metal covers, compromising durability and long-term site safety.

What is the GRP Trench Tunnel Fire and Blast Containment Wall?

A GRP trench & draw pit cover system is an engineered glass-reinforced plastic solution designed to withstand heavy loads and harsh environments, protecting trench & pit openings while maintaining structural integrity & operational safety.

 Load-Bearing Strength

Load-Bearing Strength

Engineered to support pedestrian, vehicle, and equipment loads without deformation or failure.

Chemical & Corrosion Resistance

Chemical & Corrosion Resistance

Resists oils, chemicals and moisture, outperforming standard metal covers in aggressive environments.

Thermal Stability

Thermal Stability

Maintains structural performance across a wide temperature range without warping or weakening.

 Anti-Slip Surface

Anti-Slip Surface

Provides a safe, slip-resistant walking surface to reduce the risk of falls in industrial and commercial settings.

 Low Maintenance & long Service Life

Low Maintenance & long Service Life

GRP composition eliminates corrosion, reducing maintenance needs and the total cost of ownership.

Background Pattern

How the System Protects Your Facility

Invicta ANARA’s GRP trench & draw pit cover systems integrate three connected capabilities – engineered design, certified manufacturing, and professional installation – working together to reduce risk across the project lifecycle. Covers are designed, tested, and installed to a unified quality standard, ensuring full traceability from material selection through to onsite performance.

GRP covers are rated for pedestrian, forklift, and vehicular loads, fully compliant with relevant British and European standards for industrial access covers.

Engineered to withstand exposure to oils, acids, and industrial chemicals without degrading, delivering consistent performance in aggressive facility environments.

Anti-slip surfaces meet safety standards for industrial walkways, reducing fall risk in high-traffic or wet conditions.

GRP maintains its form and structural integrity across temperature variations, ensuring covers fit reliably and perform consistently over their service life.

Lightweight panels reduce manual handling risk and enable fast, flexible installation, including retrofitting into existing trench and pit configurations.

How the System Protects Your Facility

Performance & Technical Specifications

Fire & Thermal  Protection

Fire & Thermal Protection

EI 120–240 min fire resistance (standard & high-heat variants).

Compatible with HC, RWS, and tunnel fire curves.

Prevents concrete spalling and protects steel reinforcement under extreme heat.

Smoke & Gas  Containment

Smoke & Gas Containment

Fully sealed system blocks smoke, toxic gases, and hot fire-gases.

Enables safer evacuation and rescue paths.

No hazardous post-event debris or collapse.

Blast & Impact  Resistance

Blast & Impact Resistance

Engineered to withstand high overpressure events.

Maintains structural integrity after combined fire + blast scenarios.

No hazardous post-event debris or collapse.

Materials & Construction

Materials & Construction

Non-combustible, moisture- and corrosion-resistant composite system.

Lightweight vs concrete; fast installation and easier maintenance.

Modular panels fit new builds, retrofits, and complex tunnel geometries.

Advantages Over ConventionalTunnel Protection Methods

Traditional Methods

Concrete or plain-lining risk of spalling, reinforcement failure, structural collapse under fire/heat.

Spray-applied fireproofing / fire boards / mortars may require frequent maintenance, have limited durability, may degrade upon moisture or impact

Passive fire barriers only (fire partitions, boards) limited or no blast, impact, debris, or smoke/gas protection.

Heavy & bulky steel/concrete barriers are difficult, high-cost and have long downtime for retrofit/repair.

SECURA Tunnel Wall Benefits

The composite barrier prevents spalling, maintains integrity, protects reinforcement & structure under extreme fire or blast.

Durable, moisture-resistant, corrosion-proof composite system — long lifecycle, low maintenance, high resilience.

Multi-hazard protection (fire, blast, impact, smoke/gas, thermal, acoustic), enabling comprehensive risk mitigation.

Lightweight modular panels — faster installation, retrofit friendly, minimal disruption to tunnel operations.

Sectors We Serve

Our solutions are designed for sectors where infrastructure reliability, safety, and long-term performance are critical.

Energy & Utilities

Energy & Utilities

Pattern

Energy & Utilities

  • Power & Grid Infrastructure
  • Energy & Process Facilities
  • Onshore & Offshore Assets
  • Renewable Energy Infrastructure
Industrial

Industrial

Pattern

Industrial

  • Chemical & Process Plants
  • Manufacturing & Heavy Industry
  • Hazardous Material storage facilities
  • Automotive & Industrial Campuses
Transportation

Transportation

Pattern

Transportation

  • Airports & Aviation Facilities
  • Metro, Rail & Mass Transit Systems
  • Roads, Highways & Vehicular Tunnels
  • Ports, Shipyards & Marine Transport Infrastructure
Defence

Defence

Pattern

Defence

  • Defence & Command Facilities
  • Critical National Infrastructure (CNI)
  • Secure & Hardened Assets
  • Border, Coastal & Strategic Installations
Infrastructure

Infrastructure

Pattern

Infrastructure

  • Data Centres & Digital Infrastructure
  • Public Venues & Stadia
  • Cultural & Institutional Buildings
  • Government & Diplomatic Facilities
Commercial/Mixed-Use

Commercial/Mixed-Use

Pattern

Commercial/Mixed-Use

  • Hospitality & Leisure
  • Financial & Commercial Buildings
  • Mixed-Use Landmark Developments

Certification

STRUCTURA’s solutions meet or exceed leading international standards.

EN 1363 / EN 1364 /  EN 13501

EN 1363 / EN 1364 / EN 13501

European standards governing fire resistance testing and classification for building elements

BS 476 Part 20–24

BS 476 Part 20–24

British Standard for fire testing of building materialFire resistance of elements (walls, floors, ceilings, and fire doors etc

NFPA 502 / NFPA 251

NFPA 502 / NFPA 251

NFPA 502: Standard for Road Tunnels, Bridges, and Other Limited Access Highway

CTA Background

Ready to Specify Your Cover System?

Our team can assess your facility layout and load requirements, recommending the right GRP cover configuration for your application.