Hero background
Fire-Rated Ceilings

Fire-Rated Ceilings for Cellulosic Fire Protection

Background Pattern
{Fire Containment} Is Critical.

Fire Containment Is Critical.

Buildings, commercial facilities, and power infrastructure typically encounter cellulosic fires that follow a standard time-temperature curve. Fire-rated walls and barriers are designed to withstand these conditions and limit their impact.

Contain fire within defined zones to limit building-wide spread

Shield structural elements and critical assets from direct flame exposure

Maintain thermal and structural integrity during prolonged fire exposure

Support safe evacuation by extending usable escape time for occupants

Ceilings Configurations

Transformer Room Fire-Rated Ceiling Systems

Transformer Room Fire-Rated Ceiling Systems

Background Pattern
Fire Performance and Engineering Capability

Fire Performance and Engineering Capability

  • Cellulosic fire curve compliance
  • Fire resistance up to defined durations (e.g., EI ratings)
  • Structural stability under sustained fire exposure
  • Impact and environmental durability
  • Combined fire and blast resistance

Integrated Fire Compartmentation

Fire-rated ceilings and soffit assemblies form the overhead layer of a coordinated passive fire protection strategy. SECURA systems are designed to work well with nearby fire-rated parts, making sure that fire protection is consistent throughout the whole floor area.

Penetration protection & fire-rated ceiling openings

Penetration protection & fire-rated ceiling openings

To preserve fire resistance where services pass through ceiling planes.

Fire-rated access panels and hatches

Fire-rated access panels and hatches

Maintain compartment integrity at inspection and maintenance points.

Suspended membrane ceiling assemblies

Suspended membrane ceiling assemblies

To complete horizontal fire separation between floor levels.

Ventilation & smoke containment systems

Ventilation & smoke containment systems

To support airflow management without compromising ceiling fire barriers.

Sectors We Serve

We partner with you to deliver reliable, purpose-built infrastructure that supports your goals and performs where it matters most.

Energy & Utilities

Energy & Utilities

Pattern

Energy & Utilities

  • Power & Grid Infrastructure
  • Energy & Process Facilities
  • Onshore & Offshore Assets
  • Renewables & Energy Transition
Industrial

Industrial

Pattern

Industrial

  • Chemical & Process Plants
  • Manufacturing & Heavy Industry
  • Hazardous & Controlled Storage
  • Automotive & Industrial Campuses
Transportation

Transportation

Pattern

Transportation

  • Airports & Aviation Infrastructure
  • Metro, Rail & Mass Transit
  • Roads, Highways & Vehicular Tunnels
  • Ports, Shipyards & Marine Transport
Defence

Defence

Pattern

Defence

  • Defence & Command facilities
  • Critical National Infrastructure (CNI)
  • Secure & Hardened Assets
  • Border, Coastal & Strategic Installations
Infrastructure

Infrastructure

Pattern

Infrastructure

  • Data Centres & Digital Infrastructure
  • Public Venues & Stadia
  • Cultural & Institutional Buildings
  • Government & Diplomatic Facilities
Commercial/Mixed-Use

Commercial/Mixed-Use

Pattern

Commercial/Mixed-Use

  • Hospitality & Leisure
  • Financial & Commercial Buildings
  • Mixed-Use Landmark Developments

Certification

SECURA’s solutions meet or exceed leading international standards.

EN 1363 / EN 1364 /  EN 13501

EN 1363 / EN 1364 / EN 13501

European standards governing fire resistance testing and classification for building elements

BS 476 Part 20–24

BS 476 Part 20–24

British Standard for fire testing of building materialFire resistance of elements (walls, floors, ceilings, and fire doors etc

NFPA 502 / NFPA 251

NFPA 502 / NFPA 251

NFPA 502: Standard for Road Tunnels, Bridges, and Other Limited Access Highway

CTA Background

Need Assistance in Selecting the Right Fire Protection System?

Contact us today, and let’s build safer, smarter, and stronger future solutions together.